How much is a 250 ft roll of Romex?
Compare Similar Building Wires
current product Best Seller | ||
---|---|---|
250 ft. 12/2 Solid Romex SIMpull CU NM-B W/G Wire | 100 ft. 12/2 Solid Romex SIMpull CU NM-B W/G Wire | 250 ft. 10/2 Solid Romex SIMpull CU NM-B W/G Wire |
$16500 | $10900 | $31800 |
(1146) | (2100) | (354) |
Number of Conductors 2 | 2 | 2 |
How much does a 250 foot roll of 12 2 Romex weight?
Technical Details
Manufacturer | Colonial Wire |
---|---|
Part Number | Generic |
Item Weight | 22.1 pounds |
Product Dimensions | 20 x 20 x 15 inches |
Item model number | Romex12/2 |
How many amps will 12 2 wire carry?
20 amp
Maximum Breaker Size is 30 amps. You can use a 20 amp circuit breaker with 12/2 Romex as 12/2 wire is rated for 20 amps. Always remember THE BREAKER IS THERE TO PROTECT THE WIRE NOT THE APPLIANCE !!! You can always oversize the wire , if using a 20 DPST breaker you can use 10/2 if needed…
What does a 250 foot roll of 14 2 Romex weigh?
Technical Details
Manufacturer | Southwire Retail Sales |
---|---|
Part Number | 28827455 |
Item Weight | 14 pounds |
Product Dimensions | 14 x 14 x 3 inches |
Item model number | 28827455 |
Can 12 gauge wire handle 20 amps?
“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”
How far can you run 12 gauge wire?
You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.
How much does a 250 ft roll of 14 2 Romex wire weigh?
A: This weighs 14.315 pounds.
What does a 250 foot roll of 10 3 Romex weigh?
Technical Details
Manufacturer | Southwire Company Inc |
---|---|
Item Weight | 46 pounds |
Product Dimensions | 18.1 x 19.5 x 4 inches |
Item model number | 10/3UF-WGX250 |
Is Discontinued By Manufacturer | No |
What does 250 feet of copper wire weigh?
Romex weights 26.75 lbs. on a 250 foot roll.
What size wire do I need to run 300 feet?
for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit.
How many feet can you run 12 gauge wire on a 20 amp circuit?
What is the purpose of 12 2 2 Romex?
The 12-2-2 NM cable (and 14-2-2 NM) was designed for specific uses.It is not an everyday use cable. It can be used (and in certain applications is required) for specific 3-way and 4-way lighting circuits. It can be used for ceiling fans or bathroom fans with light kits and night lights incorporated into them.
How much does 1000ft 12 2 Romex weigh?
Weight per 1000 ft: 132 lbs.
How much is a 50 foot roll of Romex?
Covers 50 ft. ($1. 55 /ft.)
How long of a run can you run 12 2 wire?
Can you use 12 2 wire to run 220?
The same 12-gauge wire can be used for a 220v, 20-amp outlet to run power tools. You need a different type of receptacle and 10-gauge cable if the appliance draws 30 Amps.
What size wire do I need for 400 feet?
Thus, in order to keep voltage drop at the camera to less than 3 volts given a camera load of 2 AMPs and a 400 foot paired wire run, we need to use a wire gauge in the range of 10-13 AWG.
How far can you run Romex wire?
As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop….For 240-volt circuits:
14 AWG | 100 feet |
---|---|
12 AWG | 120 feet |
10 AWG | 128 feet |
8 AWG | 152 feet |
6 AWG | 188 feet |
How far can I run 12 2 wire 20 amp?
After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.
What is red Romex used for?
Use it for electrical wiring of baseboard heaters. Romex SIMpull features Southwires NoLube SIM technology which has revolutionized the way wire is pulled into conduit without any pulling lubricant, saving contractors both time and money.
What is the difference between 12 2 and 12 3 Romex?
A 12-2 Romex will have a black(hot) and a white(neutral) wire as well as an unsheathed copper wire for ground. A 12-3 Romex will have a black(hot), red(hot), white(neutral), and bare copper. The red on a 12-3 is used for three-way light switches which are covered later.